Comparison of bone scintigraphy and Ga-68 prostate-specific membrane antigen positron emission tomography/computed tomography in the detection of bone metastases of prostate carcinoma


SOYDAL Ç., Nak D., ARAZ M., AKKUŞ GÜNDÜZ P., ÜRÜN Y., ÖZKAN E., ...Daha Fazla

NUCLEAR MEDICINE COMMUNICATIONS, cilt.40, sa.12, ss.1243-1249, 2019 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 40 Sayı: 12
  • Basım Tarihi: 2019
  • Doi Numarası: 10.1097/mnm.0000000000001106
  • Dergi Adı: NUCLEAR MEDICINE COMMUNICATIONS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1243-1249
  • Recep Tayyip Erdoğan Üniversitesi Adresli: Hayır

Özet

Aim This study aims to assess the diagnostic performance of Ga-68 prostate-specific membrane antigen PET/computed tomography in the comparison of planar bone scintigraphy in the detection of bone metastases. Another purpose is to define the additional benefit of bone scintigraphy subsequent to prostate-specific membrane antigen PET/computed tomography and the role of prostate-specific membrane antigen PET/computed tomography in the treatment planning. Material and method Forty-six patients with a median interval of 19 (range: 3-90) days between prostate-specific membrane antigen PET/computed tomography and bone scintigraphy included in the analysis. Diagnostic performance of both modalities was calculated and compared. Results Prostate-specific membrane antigen PET/computed tomography and bone scintigraphy were performed for initial staging in 25 (54%), for evaluation of biochemical recurrence in 11 (24%) and metastatic castration-resistant prostate carcinoma in 10 (22%) patients. In the patient-based analysis sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for bone scintigraphy for detection of bone metastases were calculated as 50%, 19-29%, 32-39%, 32-39%, and 33-39%, respectively. based on whether equivocal findings were classified as positive or negative. For prostate-specific membrane antigen PET/computed tomography, these values were found significantly higher as 100%, 95-100%, 98-100%, 96-100%, and 100%, respectively. The diagnostic performance of bone scintigraphy and PET/computed tomography in clinical subgroups was analyzed, prostate-specific membrane antigen PET/computed tomography was superior to bone scintigraphy in three groups. Conclusion In this retrospective study, prostate-specific membrane antigen PET/computed tomography was found to be superior to planar bone scintigraphy in the detection of bone metastases. Additional bone scintigraphy seems to be unnecessary in patients who underwent prostate-specific membrane antigen PET/computed tomography within three months period without additional treatment. Copyright (C) 2019 Wolters Kluwer Health, Inc. All rights reserved.