A Real-Time IoT-Based Infection Risk Sensor System for Indoor Environments: Architecture, Modeling, and Empirical Microbiological Corroboration


ÖZKAYA E., Ozkaya T. E., Oncul M. O., Oncul B.

2026 11th International Conference on Computer Science and Engineering, UBMK 2026, İstanbul, Türkiye, 16 - 18 Eylül 2026, ss.217-221, (Tam Metin Bildiri)

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Doi Numarası: 10.1109/ubmk71847.2026.11745183
  • Basıldığı Şehir: İstanbul
  • Basıldığı Ülke: Türkiye
  • Sayfa Sayıları: ss.217-221
  • Anahtar Kelimeler: BME680, ESP32, indoor air quality, infection risk index, IoT sensor system, Rudnick-Milton reformulation, Wells-Riley model
  • Recep Tayyip Erdoğan Üniversitesi Adresli: Evet

Özet

American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 241-2023, "Control of Infectious Aerosols,"specifies the equivalent clean-airflow rate that building operators must deliver to mitigate infectious aerosols, which is based on the Wells-Riley model. Meeting this standard requires sensor-based solutions that help understand and monitor the influence of clean air to infectious aerosols. The Infection Risk Sensor system presented here is one such solution, implementing it through continuous, real-time, multi-parameter monitoring. A sensor device with an ESP32 microcontroller measures equivalent carbon dioxide, temperature, relative humidity, Particulate Matter (2.5) and volatile organic compounds using a Bosch BME680 environmental sensor and a Sharp GP2Y particulate sensor. To convert these readings into an infection risk parameter, we adapt the classical Wells-Riley equation through the carbon dioxide-based reformulation of Rudnick and Milton. Taking the standard as a reference, we assumed a single infectious occupant and derived the rebreathed-air fraction from the measured carbon dioxide which we used to calculate the conditional infection probability. Temperature and humidity act as experimentally fitted virus-survival indicators, while Particulate Matter (2.5) and volatile organic compounds serve as secondary indicators of ventilation and filtration quality. These components are combined into a single weighted, normalized index that reflects the relative contribution of each parameter. The index is based the proven American Society of Heating, Refrigerating and Air-Conditioning Engineers 241-2023/Wells-Riley framework eliminating the need for separate testing. The sensors were deployed for 30 continuous days in a controlled laboratory, paired with an independent microbiological experiment conducted with Istanbul University. The biological results matched the index closely: at sensor 1 (near field), colony counts rose from 1 in the morning to 2 in the afternoon and 14 in the evening, while sensor 2 (far field) rose from 0 to 6 to 8 over the same windows, with both peaks coinciding with the index exceeding 50%. Over the month, the index reached 96% during the heating period, with the room near 26 °C and 30% Relative Humidity and carbon dioxide peaking at 8000 ppm; under these conditions, this result is consistent with the model's prediction.