Cliff-mounted glass observation platforms (GOPs) are
increasingly constructed as landmark tourist structures; however, their slender
steel support systems, low inherent damping, elevated deck mass, and
deformation-sensitive circular framing make them vulnerable to near-fault
earthquake effects. This study presents a performance-based seismic retrofit
approach for a steel observation platform using optimized fluid viscous dampers
and targeted local strengthening. The GOP in Bursa Province in Türkiye was selected
as an example. A three-dimensional structural model was developed in SAP2000
using frame elements. The seismic response was evaluated through bidirectional
direct-integration time-history analyses under selected near-fault ground
motions from the 2023 Kahramanmaraş earthquake sequence. The proposed retrofit
procedure is governed by member-level demand-to-capacity ratios, with a target
acceptance limit of D/C ≤ 0.80. A MATLAB-based iterative design routine was
used to update damper coefficients after each time-history analysis until the
prescribed performance criterion was satisfied. Within this framework, two
practical retrofit alternatives are emphasized: a sequential damper
installation strategy, in which the primary support system is first controlled
and deck dampers are subsequently optimized, and a hybrid strategy combining
viscous damping with local cross-sectional enhancement of critical circular
ring beams. The results show that the unretrofitted structure develops
excessive displacement demand and non-uniform deck deformation, particularly
around the outer ring and ramp-connected region. The sequential damper strategy
provides a balanced reduction in displacement, acceleration, and base-shear demand,
making it attractive when global response control and foundation demand are
governing design considerations. In contrast, the hybrid retrofit strategy
provides the most effective control of local deck distortion and
torsion-sensitive deformation by combining supplemental damping with increased
sectional stability of critical deck members. These findings indicate that
retrofit design for GOPs should not be based solely on global response
reduction, but should also consider local deck deformation, force transfer to
the support system, and damper utilization efficiency. The proposed framework
provides a practical design-oriented methodology for seismic retrofit of
slender steel observation platforms located in near-fault regions.