Iterative Damper Optimization for Seismic Retrofit of a Cliff-Mounted Steel Observation Platform


Kıral A., Tonyalı Z., Farzam M. F.

The 16th International Congress on Advances in Civil Engineering (ACE2026), Trabzon, Türkiye, 12 - 14 Ekim 2026, ss.1-10, (Tam Metin Bildiri)

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Basıldığı Şehir: Trabzon
  • Basıldığı Ülke: Türkiye
  • Sayfa Sayıları: ss.1-10
  • Recep Tayyip Erdoğan Üniversitesi Adresli: Evet

Özet

Cliff-mounted glass observation platforms (GOPs) are increasingly constructed as landmark tourist structures; however, their slender steel support systems, low inherent damping, elevated deck mass, and deformation-sensitive circular framing make them vulnerable to near-fault earthquake effects. This study presents a performance-based seismic retrofit approach for a steel observation platform using optimized fluid viscous dampers and targeted local strengthening. The GOP in Bursa Province in Türkiye was selected as an example. A three-dimensional structural model was developed in SAP2000 using frame elements. The seismic response was evaluated through bidirectional direct-integration time-history analyses under selected near-fault ground motions from the 2023 Kahramanmaraş earthquake sequence. The proposed retrofit procedure is governed by member-level demand-to-capacity ratios, with a target acceptance limit of D/C ≤ 0.80. A MATLAB-based iterative design routine was used to update damper coefficients after each time-history analysis until the prescribed performance criterion was satisfied. Within this framework, two practical retrofit alternatives are emphasized: a sequential damper installation strategy, in which the primary support system is first controlled and deck dampers are subsequently optimized, and a hybrid strategy combining viscous damping with local cross-sectional enhancement of critical circular ring beams. The results show that the unretrofitted structure develops excessive displacement demand and non-uniform deck deformation, particularly around the outer ring and ramp-connected region. The sequential damper strategy provides a balanced reduction in displacement, acceleration, and base-shear demand, making it attractive when global response control and foundation demand are governing design considerations. In contrast, the hybrid retrofit strategy provides the most effective control of local deck distortion and torsion-sensitive deformation by combining supplemental damping with increased sectional stability of critical deck members. These findings indicate that retrofit design for GOPs should not be based solely on global response reduction, but should also consider local deck deformation, force transfer to the support system, and damper utilization efficiency. The proposed framework provides a practical design-oriented methodology for seismic retrofit of slender steel observation platforms located in near-fault regions.