An Electrochemical Immuno-cytosensor Modified with Nanofibers for the Determination of a Carcinoembryonic Antigen


Yildizbakan Z., Altuntaş D. B., SEVİM NALKIRAN H., Aslan S., Mamuk A. E., Koçak Ç., ...Daha Fazla

Biochip Journal, cilt.18, sa.3, ss.464-476, 2024 (SCI-Expanded) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 18 Sayı: 3
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1007/s13206-024-00159-x
  • Dergi Adı: Biochip Journal
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, Chemical Abstracts Core, Compendex, EMBASE, INSPEC
  • Sayfa Sayıları: ss.464-476
  • Anahtar Kelimeler: Cancer cell lines, Carcinoembryonic antigen, Immuno-cytosensor, Nanoparticle, PAN nanofiber, Pencil graphite electrode
  • Recep Tayyip Erdoğan Üniversitesi Adresli: Evet

Özet

In this study, La0.25Fe0.75FeO3 (PNp)perovskite nanoparticle was synthesized using the sol–gel method. PNp-coated polyacrylonitrile (PAN) nanofibers were prepared by electrospinning on the pencil graphite electrode (PGE) surface. In another step, carcinoembryonic antigen (CEA) was loaded with CEA antibodies (Anti-CEA) as a biomarker receptor. Finally, PGE/PAN@PNp/Anti-CEA was used for CEA detection. Optimization steps and cell culture steps were performed using differential pulse voltammetry (DPV). The use of this composite system is a novel immunosensor development approach for label-free detection of CEA. Under optimum conditions, detection limit (LOD) of PGE/PAN@PNp/Anti-CEA immunosensor LOD 1.48 ng/mL, limit of quantification (LOQ) = 4.94 ng/mL, reproducibility 1.46% (n = 5) and R2 = 0.9984 for antigen concentration within a linear working range of 0.1–10 ng/mL. Also, immunosensor recovery in real serum samples containing dopamine and ascorbic acid was found as 98.94 ± 7.43. It has great potential in clinical screening of different cancer biomarkers. The number of cells attached to the PGE/PAN@PNp/Anti-CEA/BSA(bovine serum)/CEA surface decreased in RT-4(bladder cancer), MDA-MB-231 (triple-negative breast adenocarcinoma cell line), and T98G cells (glioblastoma multiforme cell line), which are known as CEA-negative cell lines, whereas the number of MCF-7 cells (estrogen-sensitive human breast cancer cell line, known to be CEA positive) attached to the PGE/PAN@PNp/Anti-CEA/BSA/CEA surface increased, indicating higher affinity to the immunosensor surface. As a result, while MCF-7, which is CEA positive, can be determined best when using an immune-cytosensor, the cell that can be best determined with cytosensors was found to be RT-4.