Diagnostic accuracy of non-invasive tests to screen for at-risk MASH—An individual participant data meta-analysis


Mózes F. E., Lee J. A., Vali Y., Selvaraj E. A., Jayaswal A. N. A., Boursier J., ...Daha Fazla

Liver International, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1111/liv.15914
  • Dergi Adı: Liver International
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, BIOSIS, Biotechnology Research Abstracts, CAB Abstracts, MEDLINE, Veterinary Science Database
  • Anahtar Kelimeler: at-risk MASH, FAST, FIB-4, LSM-VCTE, MASH, NFS, non-invasive tests
  • Recep Tayyip Erdoğan Üniversitesi Adresli: Evet

Özet

Background & Aims: There is a need to reduce the screen failure rate (SFR) in metabolic dysfunction-associated steatohepatitis (MASH) clinical trials (MASH+F2-3; MASH+F4) and identify people with high-risk MASH (MASH+F2-4) in clinical practice. We aimed to evaluate non-invasive tests (NITs) screening approaches for these target conditions. Methods: This was an individual participant data meta-analysis for the performance of NITs against liver biopsy for MASH+F2-4, MASH+F2-3 and MASH+F4. Index tests were the FibroScan-AST (FAST) score, liver stiffness measured using vibration-controlled transient elastography (LSM-VCTE), the fibrosis-4 score (FIB-4) and the NAFLD fibrosis score (NFS). Area under the receiver operating characteristics curve (AUROC) and thresholds including those that achieved 34% SFR were reported. Results: We included 2281 unique cases. The prevalence of MASH+F2-4, MASH+F2-3 and MASH+F4 was 31%, 24% and 7%, respectively. Area under the receiver operating characteristics curves for MASH+F2-4 were.78,.75,.68 and.57 for FAST, LSM-VCTE, FIB-4 and NFS. Area under the receiver operating characteristics curves for MASH+F2-3 were.73,.67,.60,.58 for FAST, LSM-VCTE, FIB-4 and NFS. Area under the receiver operating characteristics curves for MASH+F4 were.79,.84,.81,.76 for FAST, LSM-VCTE, FIB-4 and NFS. The sequential combination of FIB-4 and LSM-VCTE for the detection of MASH+F2-3 with threshold of.7 and 3.48, and 5.9 and 20 kPa achieved SFR of 67% and sensitivity of 60%, detecting 15 true positive cases from a theoretical group of 100 participants at the prevalence of 24%. Conclusions: Sequential combinations of NITs do not compromise diagnostic performance and may reduce resource utilisation through the need of fewer LSM-VCTE examinations.